Theoretical and experimental analysis of unbalanced doubly fed induction generators

Yaakoub Diboune, Redouane Hachelaf, Djilali Kouchih

Abstract


In this paper, a novel approach has been developed for the modeling and analysis of doubly fed induction generators operating under unbalanced load conditions. This comprehensive approach considers the derivation of the doubly fed induction generator’s neutral voltage during unbalanced conditions. Using this innovative approach, important and extremely precise signatures on stator currents and voltages have been extracted during a rational simulation time. It has been shown that for unbalanced conditions, an abnormal operation is produced. It is characterized by unbalanced stator voltages, currents, and specific harmonics through the stator variables. These harmonics have been proposed to detect unbalanced conditions. The consistency and reliability of this approach for the analysis and modeling of unbalanced doubly fed induction generators are validated by the coherence and good correlation between experimental and simulation results.

Keywords


Analysis; Diagnosis; Doubly fed induction generators; Modeling; Unbalanced conditions

Full Text:

PDF


DOI: http://doi.org/10.11591/ijra.v13i4.pp476-484

Refbacks

  • There are currently no refbacks.


Creative Commons License
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.

IAES International Journal of Robotics and Automation (IJRA)
ISSN 2089-4856, e-ISSN 2722-2586
This journal is published by the Institute of Advanced Engineering and Science (IAES) in collaboration with Intelektual Pustaka Media Utama (IPMU).

Web Analytics Made Easy - Statcounter IJRA Visitor Statistics